INDUSTRIAL GRADE SLOPED ROOF FIRE RETARDANT COATING

Certified Multi-Year Fire & Weather Protection with PermaGard Sloped Roof Coating.

Trusted by commercial roofing contractors, architects, and facility directors nationwide.

$289.00

Protect pitched roofs with Permagard Sloped Roof Coating, a premium ceramic-elastomeric waterproofing shield. Formulated with cool-roof technology, this high-build acrylic formula reflects damaging UV rays to slash cooling costs and resist thermal cracking. It creates a seamless, Class A fire-rated rubber barrier that actively blocks driving rain while inhibiting mold, mildew, and algae growth. Backed by a 20-year limited warranty, Permagard delivers elite, weather-resistant restoration for metal, tile, and wood sloped roofs.

■ Class A Fire Rated
■ Beautiful Durable Matte Finish Available in Fan Deck Colors or Custom Colors
■ Best Roof Coating for Elastomeric Waterproofing of any Sloped Roof Surface
■ Ceramic Insulating & Soundproofing Properties
■ Energy Saving Reflectivity
■ Superior Mold, Mildew and Fungi Resistance
■ Eco-Friendly, Easy Application and Water Cleanup
■ Spread Rate: 100-150 Square Feet Per Gallon
■ 20 Year Warranty
■ Quantity Discounts on 5+ Pails

Contact Us For LTL Shipping Rates!

ASTM E108 & UL 790 Class A Fire Rated

Direct-to-deck severe burning brand & flame spread rating

High Thixotropic Non-Sag Formula

Engineered for steep pitches without curtaining or slump

High Solids Content: 68% Wt. / 54% Vol.

Heavy-bodied elastomeric cross-linking matrix

Zero Toxic Halogens & Low VOC (< 25 g/L)

SCAQMD compliant non-toxic eco-safe waterborne formula

Laboratory Certified Specification
68% Solids by Weight • Class A Sloped Roof Fire Barrier

PermaGard Sloped Roof Coating

Extend the life of your roof and lower your energy bills with Permagard Sloped Roof Coating. Engineered specifically for well-draining, pitched roof systems, this premium elastomeric acrylic coating forms a seamless, rubber-like shield that protects commercial, industrial, and residential properties from harsh environmental elements. Infused with advanced ceramic particulate technology, it combines elite waterproofing, soundproofing, and thermal insulation into a single, high-build formula.

The Power of Ceramic & Elastomeric Technology

Permagard is designed to move with your building. Its highly flexible liquid-rubber composition effortlessly expands and contracts during extreme temperature shifts, resisting the thermal shock that causes lesser coatings to crack, peel, or chip.

  • Maximum Solar Reflectivity: The bright white matte finish reflects damaging UV rays away from your roof’s surface. This “cool roof” technology lowers attic temperatures, significantly reducing air conditioning strain and cutting your energy consumption costs.

  • Weatherproof Moisture Barrier: Formulated for superior resistance against driving rain, snow, and wind, Permagard locks out moisture infiltration while preventing structural decay.

  • Class A Fire Rated: Extensively tested to meet strict ASTM E84-01 and NFPA 101 Life Safety Code standards, it slows flame propagation to give occupants critical protection when it matters most.

  • Microorganism Resistance: Features built-in defenses (ASTM D 5590-00) that actively inhibit the growth of unsightly mold, mildew, algae, and fungi on your finished roof surface.

Universal Substrate Compatibility & Application

Permagard offers excellent adhesion across a broad variety of sloped surfaces, including metal roof restorations, concrete and clay tiles, slate, weathered wood shakes, plywood, and properly prepared EPDM.

It applies easily with a brush, roller, or airless sprayer (minimum 1 GPM piston type, .027 tip). Applying two uniform coats yields a heavy-duty film thickness that revitalizes old roofs at a fraction of the cost of total replacement.

Invest in 20 Years of Protection. Backed by a 20-Year Limited Material Warranty, Permagard delivers verified peace of mind and eco-friendly roof restoration. Order Permagard Sloped Roof Coating today!

Additional information

Weight 60 lbs
Dimensions 13 × 13 × 15 in

Reviews

There are no reviews yet.

Be the first to review “PermaGard”

Your email address will not be published. Required fields are marked *

ASTM E108 / UL 790

PASS • Class A

Class A severe fire hazard roof covering certification under intermittent flame exposure, burning brand, and flame spread across sloped deck assemblies.

ASTM E84 / UL 723

CLASS A (0 / 10)

Steiner Tunnel Class A rated with Flame Spread Index (FSI) of 0 and Smoke Developed Index (SDI) of 10. Does not produce heavy toxic fumes.

ASTM D6083 Compliance

100% ACRYLIC

Standard specification for 100% acrylic elastomeric liquid-applied roof coatings. Superior tensile elongation, adhesion, and accelerated weathering.

CRRC & CA Title 24

85% REFLECTANCE

Cool Roof Rating Council certified. Solar Reflectance of 85% and Thermal Emittance of 90%, slashing rooftop surface temperatures by up to 45°F.

FORMULATED SPECIFICALLY FOR COMMERCIAL SLOPED ROOFS

Why Roofing Professionals Specify PermaGard

Engineered by Nationwide Chemical Coatings to overcome common sloped roof fire and weathering vulnerabilities: wind-driven ember showers, vertical sagging on steep pitches, and UV degradation.

Class A Flame Retardancy & Ember Shield

Infused with microscopic non-toxic ceramic and mineral fire shields that release bonded chemically bound hydrates when exposed to direct rooftop ignition. It starves surface fires of oxygen and cools combustible underlying wood, insulation, and membrane substrates.

  • Meets UL 790 / ASTM E108 Class A on combustible roof decks
  • Extinguishes flying embers and airborne firebrands
  • Complies with California Title 19 & WUI building codes

High-Thixotropy Non-Sag Rheology

Unlike standard runny paints or elastomeric coatings that sag, slump, and puddle downward on pitched inclines, PermaGard features an engineered high-viscosity structure (110–125 KU) that clings evenly to vertical standing seams, corrugations, and high-pitch slopes.

  • Maintains uniform mil thickness across steep roof slopes
  • Zero curtaining, running, or edge thinning on standing seams
  • One-pass build saves labor hours on steep-slope jobs

300%+ Tensile Elongation & Cool Roof

Extreme building movement, daily expansion and contraction on metal standing seams, and freeze-thaw cycles will not crack or shear this membrane. Reflects 85% of solar rays, lowering roof deck temperatures by up to 45°F and significantly reducing HVAC utility costs.

  • Elongation > 300% at 77°F (ASTM D2370)
  • Reflects 85% Total Solar Heat (CRRC & Title 24 Approved)
  • Bridges micro-fissures and seals fastener penetrations

UNIVERSAL SLOPED ROOF COMPATIBILITY

Approved Sloped Roof Substrates & Surface Preparation

PermaGard chemically bonds to all major commercial, industrial, agricultural, and residential sloped roof substrates to provide monolithic fire defense and waterproofing.

Recommended Sloped Roof Assemblies

Commercial Sloped Standing Seam & Metal Decks
Direct-to-metal adhesion over galvanized steel, Galvalume, corrugated panels, R-panel metal buildings, and coated aluminum. Seals exposed fasteners, lap seams, and ridge caps against wind-driven ember infiltration.
Asphalt Shingles & Fiberglass Shingle Roofs
Rejuvenates dried asphalt binders, locks down granular mineral surfacing, prevents tab blow-off during windstorms, and seals against firebrand penetration into roof sheathing.
Wood Shakes & Architectural Cedar Shingle Decks
Transforms high-risk raw or aged cedar shake roof assemblies into fire-resistant Class A/B shields meeting Wildland-Urban Interface (WUI) standards.
Concrete & Clay Sloped Roofing Tiles
High-traction acrylic bond seals porous barrel tiles, clay tiles, and slate roofs against wind-driven embers, water absorption, and freeze-thaw spalling.

Surface Preparation & Application Guidelines

1. High-Pressure Washing (2,500 – 3,000 PSI)
Roof surface must be free of grease, moss, algae, biological growth, dirt, and loose roof granules. Use biodegradable TSP substitute cleaner where needed; rinse thoroughly and allow to dry.
2. Seam, Flashing & Fastener Reinforcement
Inspect all ridge caps, valleys, sidewall flashings, skylight curbs, and fasteners. Pre-treat penetrations and seams with Nationwide Elastic Mastic reinforced with stitch-bonded polyester fabric before coating.
3. Priming Guidelines for Corroded Metal & Aged Asphalt
Rusty metal requires wire brushing and spot-priming with Nationwide Metal-Lok Rust Inhibitive Primer. For non-ferrous aluminum or slick factory finishes, apply an adhesion promoter primer.
4. Weather & Temperature Application Window (50°F – 100°F)
Apply only when ambient and surface temperatures are between 50°F (10°C) and 100°F (38°C), and at least 5°F above dew point. Do not apply if rain, fog, or freezing temperatures are expected within 24 hours.

LABORATORY VERIFIED METRICS

Technical Specifications & Engineering Data

Comprehensive physical, chemical, fire endurance, and weathering performance metrics for PermaGard Sloped Roof Coating.

Specification Metric Observed Engineering Value Standard / Test Method
Physical State & Appearance Thick, viscous liquid; dries to flexible white elastomeric membrane Visual / Sensory Inspection
Solids Content by Weight 68.0% (± 2.0%) ASTM D2369 / Glass Plate
Solids Content by Volume 54.0% (± 2.0%) ASTM D2697
Specific Gravity / Density 1.34 – 1.38 g/cm³ (11.2 – 11.5 lbs/gal) ASTM D1475
pH Balance 8.5 – 9.2 (Mild Alkaline) Standard pH Probe
Viscosity (Non-Sag Rheology) 110 – 125 Krebs Units (KU @ 77°F / 25°C) ASTM D562 (Stormer)
Tensile Strength & Elongation > 320% Elongation @ break; 280 PSI Tensile ASTM D2370 / ASTM D6083
Flash Point Non-Flammable (Waterborne Acrylic Elastomer) Pensky-Martens Closed Cup
Theoretical Coverage Rate 100 sq. ft. / gallon per coat (dries to ~8.6 mils DFT per coat) Calculated Volume Solids
Dry-to-Touch / Recoat Time Dry to touch: 2–4 hours; Recoat: 12–24 hours @ 77°F, 50% RH ASTM D1640
Shelf Life 3 Years in unopened container (Store 50°F–90°F) Accelerated Stability Testing
Fire Certification Metric Observed Engineering Value Standard / Test Method
Sloped Roof Fire Hazard Classification Class A Certified Roof Covering ASTM E108 / UL 790
Flame Spread Index (FSI) 0 (Zero Flame Spread) • Class A ASTM E84 / UL 723 (Tunnel)
Smoke Developed Index (SDI) 10 (Minimal Smoke Generation) • Class A ASTM E84 / NFPA 255
Burning Brand Resistance Class A Burning Brand Test • Passed Direct Exposure UL 790 Section 7
Intermittent Flame Exposure 15 Cycles of 4-minute gas flame application • No ignition ASTM E108 Section 6
Building Code Approvals Meets IBC Section 1505.1 & IRC Section R902.1 for Class A Roofs International Building Code
State Fire Marshal Listing California State Fire Marshal (CSFM) Title 19 & WUI Chapter 7A CA Title 19 / WUI Compliant
Weathering & Environmental Property Observed Engineering Value Standard / Test Method
Total Solar Reflectance (TSR) 85% Initial Solar Reflectance ASTM C1549 / CRRC Certified
Thermal Emittance 0.90 Thermal Emittance ASTM C1371
Solar Reflectance Index (SRI) 106 Initial SRI (Cool Roof Rating) ASTM E1980 / Title 24
Accelerated Weathering (QUV) 3,000 Hours • No cracking, checking, or flaking ASTM G154 / ASTM D6083
Low Temperature Flexibility Passes 1/2″ mandrel bend at -15°F (-26°C) without cracking ASTM D522
Volatile Organic Compounds (VOC) < 25 g/L • Ultra-Low VOC EPA Method 24 / SCAQMD
Toxicity & Leaching Resistance Zero Halogens, Zero Heavy Metals • Non-leaching cured matrix EPA TCLP 1311 Certified

STANDARD INDUSTRIAL WORKFLOW

How to Apply PermaGard Sloped Roof Coating

Follow these verified field application procedures to ensure monolithic weather protection and fulfill full Class A fire endorsement warranties.

1

Surface Prep & Detailing

Power wash roof at 2,500–3,000 PSI to remove dirt, oxidation, loose granules, and chalking. Detail all valleys, penetrations, flashings, skylights, and fasteners with Nationwide Elastic Mastic and reinforcing fabric.

2

Mechanical Agitation

PermaGard contains high-density solids (68% wt). Power mix using a heavy-duty electric drill with a spiral paddle for 3–5 minutes until completely smooth and creamy. Do not thin or dilute with water.

3

Airless Spray Application

Apply using an industrial airless sprayer (min. 2,500–3,000 PSI, flow >1.5 GPM, reversible tip size .025" to .031"). Spray two coats in cross-hatch passes at 100 sq. ft. per gallon per coat to ensure 16–18 mils total dry film.

4

DFT Mil Gauge Inspection

Inspect total cured membrane thickness using a dry film comb or ultrasonic gauge. Verify vertical seams and high-pitch transitions have achieved full continuous coverage before issuing final sign-off.

COMMON QUESTIONS

Frequently Asked Questions

Everything you need to know about sloped roof fire retardancy, non-sag rheology, equipment, and building code sign-offs.

PermaGard is formulated with higher thixotropic rheology (viscosity 110–125 KU) to prevent sagging, slumping, or running on steep-pitch architectural roofs, standing seam metal, and steep asphalt shingle inclines. While Permakote Plus is cross-linked specifically for dead-flat zero-pitch ponding water submersion, PermaGard excels on inclines, valleys, and ridges where uniform dry film thickness (DFT) must be maintained across vertical contours without pooling at eaves.
Yes. PermaGard exhibits outstanding direct-to-substrate adhesion over weathered asphalt shingles, fiberglass shingles, and aged wood/cedar shake roofs. It locks down loose mineral granules, bridges hairline aging cracks, and transforms combustible wood assemblies into Class A/B fire-retardant barriers in compliance with Wildland-Urban Interface (WUI) standards.
No. PermaGard is a fully cross-linked 100% acrylic elastomeric polymer matrix that cures into an insoluble, non-leaching rubberized shield. Unlike interior water-soluble fire retardant salts that degrade when exposed to moisture, PermaGard's proprietary ceramic fire-suppressive minerals remain permanently locked inside the elastomeric film through decades of torrential rain, hail, and snow.
We recommend an industrial airless spray pump with a minimum rating of 2,500–3,000 PSI and a flow rate of at least 1.5 GPM (e.g., Graco Ultra Max II 795 or larger). Use a reversible spray tip with an orifice size between .025" and .031". Remove the gun filter or use a coarse 30-mesh manifold filter to prevent tip clogging with high-solids fireproofing pigments.
Yes. PermaGard has undergone full-scale laboratory testing under ASTM E108 and UL 790, earning the highest Class A fire rating over combustible and non-combustible roof decks. It meets International Building Code (IBC) Section 1505.1, International Residential Code (IRC) Section R902.1, and California State Fire Marshal (CSFM) Title 19 standards. National Fireproofing Supply Co. provides official submittal packets with certified lab test reports for code officials.

DIRECT TECHNICAL SUPPORT

Need a Custom Submittal, Sloped Roof Calculation?

Commercial fireproofing tech support regarding measurements, pitch calculations, custom submittal packets, and bulk job site delivery nationwide.

Direct Phone Line
+1 (219) 926-1477
Engineering Desk Hours
Mon – Fri: 8:00 AM – 5:00 PM CST

Request Submittal Packet & Contractor Quote

Receive ASTM laboratory test certificates, technical data sheets, and immediate volume pricing.

Sloped Roof Coating Support

Name(Required)
Company / Roofing Firm