Description
Technical Downloads
- TDS
- 1″ Sleeve Drawing
- 2″ Sleeve Drawing
- 4″ Sleeve Drawing
- Cable Load Chart
- Fill Calculation
- UL W-L-3273 3 & 4hr Wall
- UL 3082 F 2hr Wall Assembly
- UL W-L-3234 3 & 4hr Drywall
- UL W-L-3233 1 & 2hr Drywall
- UL W-J-3112 4hr Concrete
- UL W-J-3111 2hr Concrete
- UL F-A-3019 2 & 3hr Vertical Concrete
- UL W-L-3122d Leakage Rating
- Hilti W-L-0023 (empty 2 or 4 inch sleeve systems)
- Hilti W-L-3122 (cable bundle)
- 3M Threaded Firestop/Penetrator System
Trust in UNIQUE’s threaded firestop sleeves for your new cable installations. This UL Classified system is designed with tough steel tubing and can withstand up to 4 hours horizontally and 3 hours vertically. Made in the USA, this product is the top choice for cable protection. With a variety of sizes available for immediate shipping that you can rely on for quick and efficient service. For custom applications, our manufacturer can provide you with specialized systems in just 24 hours. Each system includes all necessary components, including high-quality intumescent putty. Rest assured that with UNIQUE products, you have everything you need for a secure and reliable installation. Whenever there are new installations of cables and the opening in the firewall or on the floor is either precut or core bored, then the UNIQUE Threaded Firestop Sleeves become the ideal choice.
System Contents
*The threaded firestop sleeve comes with all the required essentials, including intumescent putty.
1 – 12″ Nipple IMC Sleeve
2 – Big flat washers
2 – Threaded couplings
2 – Bushings plenum rated
2 – Stickers/Warning signs
1 – UNIQUE Intumescent Putty
In general, all firestop sleeve systems and endcap systems of UNIQUE have what is usually considered an average 22% cable load and a max 48% cable load. Most installers think that’s regular, but sometimes situations can be different. If a firestop cable sleeve is installed with less than 25% cable load is done, more intumescent putty will need to be used in the sleeve system to bring the firewall rating back. That extra putty is actually provided for that reason; it helps so smoke, flames, or other gases don’t get through the house before it’s time to leave the building, which is very important in emergencies. For the right way to fill putty, based on how it’ll be used, consult a UL System page that was made for that process. Order an additional intumescent Putty Fill Kit here.
Disclaimer: Use the product as directed. If the product is proven to be defective, Sellers and Manufacturers will only replace the defective quantity. Neither Seller nor Manufacturer are liable for any injury, loss, or damage, direct or consequential, from the use of the product. The user is solely responsible for any risks and liability associated with the product. Any additional statements or recommendations not included in this agreement are not valid unless signed by officers of the Seller and Manufacturer.